1.7 The EMC requirements
The device complies with the requirements of EN61800-3:2004 (IEC61800-3) for second environment, category
C3, when a dedicated external EMC filter is applied.
1.7.1 EMC filter connection to inverter for trolley travelling.
DMCS007
c_kc310a
1. Supply
2. EMC filter KC-310-00
3. Inverter
4. Motor cable length max 3 m
5. 4 x 0,47
µ
F
Capacitors have to be placed as near the inverter as possible.
1.7.2 EMC filter connection to inverter for bridge travelling.
DMCS007
c_kc330a
1. Supply
2. EMC filter KC-330-00
3. Inverter
4. Motor cable length max 25 m
5. 4 x 1
µ
F
6. Input wires two times trough input ferrite rings
Capacitors have to be placed as near the inverter as possible.